Description: B&K Mfg V O Matic 360 Analog Automatic Volt-Ohm-Milliammeter in Bakelite case.
Ranges:
- DC Volts: 250 millivolts, 3V, 15V, 60V, 300V, 1,000V, and 6,000V
- DC Current: 100 microamps, 5 milliamps, 100 milliamps, 500 milliamps, and 10 amps
- AC Volts: 3V, 15V, 60V, 300V, 1,000V, and 6,000V
- Resistance 1,000 ohms, 10,000 ohms, 1Meg, and 100Meg.
Requires 1-1/2 volt and a 9 volt battery, and does not have test leads. Unit has not been tested. Manual is available in PDF format. (circa 1960's).
Description: Crosley Model 50 - Regenerative Receiver (circa 1920's.) One-tube regenerative receiver in a wooden case. It requires both 6-volt and 22.5-volt batteries, and drives high impedance headphones. Unit has not been tested.
Description: "Donner Scientific Model 50 - Comparator Bridge, (circa 1950's.) The Donner Model 50 is used as a precision voltage source and comparator of voltages in the range of -100 V to +100 V. Does not have test leads. Unit has not been tested.
AC Power Cord needs replacement.
Description: Eico Model 221 - Electronic Voltmeter / Ohmmeter (VTVM).
Ranges:
- DC Volts: 5V, 10V, 100V, 500V, 1,000V
- AC Volts: 5V, 10V, 100V, 500V, 1,000V
- Resistance 1,000 ohms, 10,000 ohms, 1Meg, 10 Meg, and 1,000 Meg.
- DB -20 to +55
With test leads. Requires 1-1/2 volt battery, Unit has not been tested. Manual is available in PDF format.
Description: Eico Model 232 - Electronic Voltmeter / Ohmmeter (VTVM).
Ranges:
- DC Volts: 1.5V, 5V, 15V, 150V, 500V, 1,500V
- AC Volts: 5V, 15V, 50V, 150V, 500V, 1,500V
- Resistance RX1, RX10, RX100, RX1,000, RX10K, RX100K, RX1Meg.
Has test Probe. Requires 1-1/2 volt battery. Unit has not been tested. Manual is available in PDF format
Description: Heathkit Model AR-3 - AM/CW/SW Amateur Receiver, "This 5-tube receiver can listen to communications from 550 kc to 30 mc in four bands. Transformer power supply. The case does not have a back. Unit has not been tested. Manual is available in PDF format. (Circa 1955 — 1961)
Description: Heathkit Model IG-102 - RF Signal Generator #1. This is a basic tube signal generator with a frequency range of 100 kc to 110 mc in 5 bands (100 to 220 mc on calibrated harmonics). Comes with leads shown (Amphenol connector to alligator clips.) Unit has not been tested. Manual is available in PDF format.
An article on converting the IG-102 to solid-state appeared in the May 1978 issue of "73 Magazine" page 120.
Description: Heathkit Model IG-102 - RF Signal Generator #2. This is a basic tube signal generator with a frequency range of 100 kc to 110 mc in 5 bands (100 to 220 mc on calibrated harmonics), Comes with test leads shown (Amphenol connector to male BNC connector). Units have not been tested. Manual is available in PDF format.
An article on converting the IG-102 to solid-state appeared in the May 1978 issue of "73 Magazine" page 120.
Description: IBM multi-meter in leather case, Model 200C.
Ranges:
- DC Volts: 1.5V, 5V, 15V, 50V, 150V, and 500V
- DC Current: 500 mA, 50 mA, 5 mA and 0.5 mA.
- AC Volts: 15V, 50V, 150V, and 500V
- Resistance: x1, x10, x100, and x1K.
Does not have test leads. Unit has not been tested.
Description: James Millen Grid-Dip Meter with seven coils in original box and instructions, Model 90651. Includes the seven band plug-in coils to give it a range from 1.7 to 300 MC. In excellent shape, coils in metal holder. Unit has not been tested.
Description: Micronta 43 Range ("Range Doubler") multimeter, Model 22-204C.
Ranges:
- DC Volts: 125mV, 250mV, 1.25V, 2.5V, 5V, 10V, 25V, 50V, 125V, 250V, 500V, and 1KV.
- DC Current: 25µA, 50µA, 2.5mA, 5mA, 25mA, 50mA, 250mA, 500mA, 5A, and 10A.
- AC Volts: 5V, 10V, 25V, 50V, 125V, 250V, 500V, and 1,000V
- Resistance 2KΩ, 20KΩ, 200KΩ, 2MegΩ, and 20MegΩ.
- DB (V-A/2): -20 to +16, -6 to +30, +8 to +44, +20 to +56.
- DB V-Ω-A): -14 to +22, 0 to +36, +14 to 50, +26 to +62 (0dB = 1mW 600Ω).
Requires 1-1/2 volt and 9 volt battery, with test leads and instruction manual. Unit has not been tested.
Description: RCA Transistor Tester, Model WT-501A. This is an out-of-circuit and in-circuit transistor tester for transistors and diodes. Requires two 1-1/2 volt batteries, comes with test leads. Unit has not been tested. Manual is available in PDF format.
Description: The RCA WV-98C Senior VoltOhmyst is an all electronic voltmeter designed to measure DC voltages, resistance, AC RMS values of sine waves, and AC peak-to-peak values of Complex waves. Requires 1-1/2 volt battery. Includes WG-299E probe and leads. Unit has not been tested. Manual is available in PDF format.
Description: Sanwa Multimeter in Bakelite case, Model 305-G TR.
Ranges:
- DC Volts: 0.25V, 1V, 5V, 25V, 250V, and 1KV
- DC Current: 50 µA, 500 µA, 2.5 mA, 25 mA and 250 mA.
- AC Volts: 1.5V, 10V, 50V, 250V, and 1KV.
- Resistance: 1R, 10R, 100R, and 1,000R.
Requires 1-1/2 volt batteries, and does not have test leads. Unit has not been tested.
Description: The Sencore DVM37 is an accurate portable DVM. It features automatic Auto Zero, Polarity, Decimal, and Over-range. It is fully protected inside to over 2000V on all functions, including Ohms, and comes with attached test leads. Unit has not been tested.
Description: The Sencore PS-103 Transi-Pak is an adjustable power supply for transistorized equipment that provides from 0 to 24 VDC, with a switchable metered voltage and current output. It can supply up to 100 M.A. continuous, with a 200 M.A. peak, with instruction manual. Unit has not been tested.
Description: The Sencore FE14 Field Effect Meter is a combination meter of a VTVM and a VOM. It has high input impedances on both AC and DC voltage ranges (10 megohms and 15 megohms.)
Ranges:
- DC Volts: 0 to 1, 3, 10, 30, 100, 300 and 1,000
- DC Current: 0 to 100 µa, 1ma, 10ma, 100ma, and 1 Amp
- AC Volts: 0 to 1, 3, 10, 30, 100 and 1,000
- Ohms: R x 1, R x 10, R x 100, R x 10K, and R x 1MEG
Requires 1-1/2 volt and 9 volt batteries, with has test leads. Manual is available in PDF format. Unit has not been tested.
Description: The Sencore TRC-4 transistor and rectifier checker is designed to test transistors for opens, shorts, leakage, and current gain. TRC-4 can also be used to check rectifiers, and crystal diodes. Comes with an instruction manual, and the unit has not been tested
Description: The Simpson Model 381 Capacity Bridge is intended for measuring the quantity of capacity in any ordinary condenser in four ranges.
- Range 1: 20 µµfd to 500 µµfd,
- Range 2: 0.0005 µfd to 0.05 µfd,
- Range 3: 0.05 µfd to 5 µfd,
- Range 4: 5 µfd to 500 µfd.
The unit does not have any test leads, and the unit has not been tested.
Description: The Triplett Model 2006 is designed for testing electric household appliances. Full range coverage provides simultaneous readings of line voltage and current drain. The twin style AC- DC Ammeter on the left and the AC-DC Voltmeter on the right provide readings of both Volts and Amperes.
Ranges:
- Amps: DC-AC: 0-25.
- Volts: DC-AC: 0-130-260.
Description:
Description:
This equipment was for sale by Paul Whitely - WA6GFT and is no longer available.
The equipment is located in the City of Tustin, CA, and is "available by pickup only." Prices are negotiable.
These items are from my Fathers and Grandfathers estate, and if you want something tested, let me know. The results may influence selling price, one way or the other!